Every sign in a multi-family package: a takeoff checklist by area
From address numbers to stair signs, leasing office to back of house: the sign types in an apartment package, which ones a code requires and which ones are the owner's program, and how to count them.
A multi-family sign package runs from the site (entry and address signs, accessible parking) through the leasing office and amenities, the corridors and apartment doors, the stairs and elevators, to back-of-house rooms. Some signs are code-required, like stair identification signs (IBC 1023.9), elevator fire signs (IBC 3002.3) and address numbers (IFC 505.1). Others, like apartment door signs, are the owner's program, because the ADA doesn't cover private apartment doors.
Key takeaways
- Sort every sign into code-required or owner's program before you price it; the takeoff, the schedule and the open items all depend on it.
- The ADA covers the leasing office and any amenity the public can use, not private apartment doors. Apartment door signs are the owner's spec.
- Interior exit stairs connecting more than three stories get a stair identification sign at each floor landing (IBC 1023.9) and a tactile floor-level sign at each corridor door (IBC 1023.11).
- Every elevator call station gets the fire sign: IN CASE OF FIRE, ELEVATORS ARE OUT OF SERVICE. USE EXIT STAIRS. (IBC 3002.3).
- Count by building, floor, stair and elevator, not from one floor plan: a multi-family package multiplies.
On this page
A large multi-family project means a sign for every unit, amenity and door, a takeoff before every bid and a permit set for every building. That's the work our workflows were built on at Zealot Signs. The checklist below goes area by area and says, for each sign, whether a code requires it or the owner's program does.
- 1Entry or monument signThe owner's program, with a sign permit where the zoning code requires one
- 2Address numbersIFC 505.1: visible from the street, 4 inches high minimum, 1/2-inch stroke
- 3Accessible parkingADA 502.6 and IBC 1112.1: ISA, van accessible, 60 inches to the bottom
- 4Leasing office room IDs and restroomsADA 216.2: the leasing office is a public accommodation
- 5Amenity room IDsADA where the public can use them; posted occupant load in assembly rooms (IBC 1004.9)
- 6Apartment entry signsThe owner's program: the ADA doesn't cover private apartment doors
- 7Corridor directional signsThe owner's program: unit ranges, amenities, elevators and stairs
- 8Stair identification signsIBC 1023.9: each floor landing, bottom 5 feet minimum above the landing
- 9Tactile floor-level and EXIT signs at stair doorsIBC 1023.11 and 1013.4: raised characters and braille beside the door
- 10Elevator fire signsIBC 3002.3: beside every call station on every floor
- 11Area of refuge signsIBC 1009.9 to 1009.11, where the building has areas of refuge
- 12Mail and package roomThe owner's program
- 13Fire riser and control roomsIFC 509.1: identified for the fire department, wording the fire official approves
- 14Pool and amenity rulesThe state or county health code, where there's a pool
Who requires what
The rule that trips up multi-family takeoffs: the ADA doesn't apply to strictly residential facilities. A rental office is a place of public accommodation, and common areas are covered only if they aren't limited to residents and their guests. The Fair Housing Act's design rules cover public and common use areas and the units, but they list no signage. The building and fire codes cover the stairs, elevators, exits and address numbers wherever they're adopted.
| Area | What applies | Source |
|---|---|---|
| Leasing office | The ADA: it's a place of public accommodation | DOJ ADA Title III Technical Assistance Manual, III-1.2000 |
| Amenities | The ADA only if people other than residents and their guests can use them; otherwise the Fair Housing Act | DOJ; HUD Fair Housing Act Design Manual |
| Apartment doors | Not the ADA; the Fair Housing Act lists no signage, so apartment door signs are the owner's spec | 24 CFR 100.205; HUD |
| Stairs, elevators, exits, areas of refuge | The building code, where adopted | IBC 1009, 1013.4, 1023.9, 1023.11, 3002.3 |
| Address numbers, fire equipment rooms | The fire code, where adopted | IFC 505.1, 509.1 |
| Accessible parking | The ADA where it applies, and the building code's ISA signs; spaces assigned to specific units are exempt | ADA 502.6 and 216.5; IBC 1112.1 |
The checklist, area by area
Site and parking
- Entry or monument sign: the owner's program, with a sign permit where the zoning code requires one.
- Address numbers on every building: visible from the street, contrasting with the background, at least 4 inches high with a 1/2-inch stroke, and never spelled out (IFC 505.1).
- Accessible parking signs: the International Symbol of Accessibility, "van accessible" at van spaces, and the bottom of the sign at least 60 inches above the ground (ADA 502.6). Lots with four or fewer spaces, and spaces assigned to specific units, are exempt (216.5).
- Building, entrance and visitor signs: the owner's program.
Leasing office and amenities
- Leasing office room IDs and restrooms: raised characters and braille under the ADA (216.2), because the office is a public accommodation.
- Amenity room IDs (clubroom, fitness, business center): tactile where the ADA applies, and the owner's standard where it doesn't.
- Posted occupant load in assembly rooms such as a clubroom, where the building code requires it (IBC 1004.9).
- Pool signs: the state or county health code sets them; check it before you price the package.
Corridors and apartments
- Apartment entry signs: the owner's program. The ADA doesn't cover private apartment doors and the Fair Housing Act lists no signage, so the size, the copy and whether they're tactile are the owner's spec.
- Directional signs to unit ranges, amenities, elevators and stairs, at each corridor decision point.
- Room IDs for trash, mail and package rooms and other resident common rooms.
Stairs and elevators
- Stair identification signs at each floor landing in interior exit stairways connecting more than three stories: the floor level, the top and bottom terminus, the stair's ID, the story of and direction to the exit discharge, and roof access. The bottom of the sign sits at least 5 feet above the landing, and the sign is at least 18 by 12 inches (IBC 1023.9).
- Tactile floor-level signs in visual characters, raised characters and braille at each floor-level landing beside the door into the corridor, where floor-level signs are provided (IBC 1023.11).
- Raised-character and braille EXIT signs at the doors to exit stairways, exit passageways and exit discharge (IBC 1013.4).
- Elevator fire signs beside every call station on every floor: IN CASE OF FIRE, ELEVATORS ARE OUT OF SERVICE. USE EXIT STAIRS. (IBC 3002.3). Elevators that are part of an accessible means of egress are an exception.
- Area of refuge signs, directions and instructions, where the building has areas of refuge (IBC 1009.9 to 1009.11).
Back of house
- Fire riser and fire alarm control rooms, identified for the fire department, durable and readily visible, in the wording the fire official approves (IFC 509.1).
- Electrical, mechanical, telecom and storage rooms: the owner's program, unless the space is in an ADA-covered area.
How to count it
Count by building, then floor
So the takeoff lines up with phasing, and with a permit set for every building.
Take apartment signs from the unit matrix
Not from one floor plan. Confirm the unit numbers the owner will use; they can differ from the plan's.
Count stairs by landing
One stair identification sign per floor landing per stair, and one tactile floor-level sign per corridor door.
Count elevators by call station
One fire sign per call station on every floor.
Count directional signs by decision point
Every elevator lobby and corridor junction, on every floor.
Sort the list
Mark each line code-required, the owner's program or open, so the client sees what they're choosing and what they aren't.
What changes with a takeoff workflow
On a multi-family job the takeoff multiplies: the same sign family repeats on every floor of every building, and one missed stair landing repeats with it. The takeoff workflow reads the plans floor by floor, places and counts every sign, schedules the copy and braille and lists the open items, and your estimator checks it. See a real takeoff, sheet by sheet, on the sign takeoff workflow page, and the rules behind tactile signs in the ADA sign takeoff checklist.
Sources
- DOJ: ADA Title III Technical Assistance Manual, III-1.2000
- HUD: Fair Housing Act Design Manual, chapter 2
- 24 CFR 100.205: design and construction requirements (Fair Housing Act)
- 2010 ADA Standards for Accessible Design (216, 502.6, 703)
- IBC 2021 chapter 10, means of egress (1009, 1013, 1023), via UpCodes
- IBC 2021 chapter 11, accessibility (1112), via UpCodes
- IBC 2021 chapter 30, elevators (3002.3), via UpCodes
- IFC 2021 chapter 5, fire service features (505, 509), via UpCodes